RailCommand Command Center

Last verified: November 19, 2026

Concept

The Command Center (/app/railcommand) is RailCommand's home page. It frames one layout and, when one is running, one exact operating session, and it shows the same truth the CTC board shows for that layout. A status ribbon across the top names the state in a word with an icon and a colour, says what the state means, and lists eight fields: layout, session, railroad clock, role, territory, runtime mode, feed and authority, and health.

When an admitted exact session is running and the layout has a CTC panel, that real board is the main operating view. Command requests, Crew assignments visible to you, and Organization and network alerts load independently beside or below it. Hide session context hides these views without closing the board or stopping their readers. The board keeps its selected board, signal and zoom across same-session workspace refreshes and context visibility changes. A session hosted by a RailCommand computer still uses the board's existing viewing-only controls and named limitations; embedding it does not add a browser relay.

The crew list contains only active assignments the server makes visible to you for this session. An empty list does not establish that nobody is assigned. Names, roles, territories, duty minutes and on-duty limits are as last read, not a complete staffing or readiness assessment. Duty minutes are not advanced locally, and an on-duty limit that is not supplied is not unlimited. This view does not decide eligibility, assign a crew or release an assignment. Communications and other staffing context are not available here yet.

Crew requirements are decided by the effective rules for the session's curated operating day, separately from this assignment list. Published defaults require one Engineer and one Conductor per train, one Fireman in Early Steam and Late Steam, and one Brakeman before the rule's 1985 cut-over year. The owner can amend the number of positions and the offered cut-over option under Operating Rules > Train crew. A role may require several numbered positions, so seeing one holder does not establish that the role is fully staffed. These editable product defaults are not universal historical or legal requirements.

Use Crew Management for the exact session to Fill open jobs with NPC crew. It preserves human-held positions and calls a capable NPC for each rule-required open train/role/position through ordinary Crew Call, reporting each outcome. Its operating year comes from the session era's authoritative current episode date. If that curated day is unavailable or ambiguous, the fill refuses before filling jobs; the computer's date cannot replace it. Filling calls no AI model and starts no automatic operating loop. A filled assignment is not permission for unattended physical operation: a person must be present at the layout and accountable for it, and the native layout engine still owns authority, safety and actuation. Refreshing the Command Center's crew list only reads assignments again.

Organization and network alerts use the existing COO alert source in the selected running session's resolved operating era, after checking your exact session admission. Their scope is wider than that session: they are not local signal holds or a safety verdict. The pane shows the source read time in UTC and the source's tag, body, severity and decision-by value as returned. It does not acknowledge or resolve an alert, advance a deadline locally or change a signal. An unresolved era is unavailable, never a default era. A successful empty read says only that this source returned no alerts.

The page is in one of eight states:

  • NO LAYOUT: no layout is selected. If your organization has exactly one layout, the Command Center opens on it; with several, it asks you to choose one.
  • NOT RUNNING: no operating session is running on the layout. The page offers Start an operating session, lists sessions that are being set up or are paused, shows the layout's readiness, and lists recent sessions.
  • STARTING: the session is being set up, or you are joining it: you have not joined it yet, or you have joined and are waiting to be admitted to a role.
  • SIMULATION: one session is running its simulation.
  • LIVE: one session is running the physical railroad, with its feed connected.
  • FEED DOWN: one session is running, but the railroad's live feed is not connected or the hosting computer has stopped reporting. The page never calls this a simulation.
  • SEVERAL SESSIONS: more than one session is running on the layout and none has been chosen. Choose one to open it.
  • ENDED: the chosen session has ended. Its times and its record are shown.

The Command Center uses the layout's only running session when there is one. It never chooses among several running sessions: it asks you to choose, and every link it offers names the exact session it is about.

While the page remains open, it checks the workspace every 15 seconds through the same authoritative read. This reconciles a host report that expires without another notification, a session ending, admission, role and territory changes, and the web simulation's own railroad clock. A read has a 15-second display budget: a changed state is reflected, or the previous ribbon is replaced by an explicit read error, within 30 seconds while the interactive page is running. Background checks do not repeat a join or operating command. The page does not advance a clock itself or invent the hosting computer's time. A reported hosting-computer clock has a separate display deadline: when its accepted board report expires, the clock field becomes unavailable without waiting for the next workspace check. This does not advance the railroad clock or change the workspace polling interval.

Dispatcher (/app/railcommand/dispatcher) is a launcher into the Command Center. Each layout card shows the same state the Command Center shows for that layout, the running count is the number of operating sessions running across your layouts, and Open in Command Center opens the layout there.

How To

Getting back. Every RailCommand page shows a trail at its upper left, before the page's heading: Command Center, then the layout by name, then any page it opens from, then the page itself. Click any part to go back to it; the layout's name opens the layout page on the tab the page belongs to. The trail is the same after a refresh or when you open a page from a saved link. On the Layout Editor, the CTC board and the panel designer it sits in their own toolbar or header; while the Layout Editor loads, or before it has a panel, it sits at the editor's upper left.

  1. Open Command Center from the RailCommand menu. With one layout, it opens on that layout. With several, choose one; Change layout on the ribbon brings the choice back.
  2. When the state is NOT RUNNING, press Start an operating session to create one for the layout. Readiness is guidance only: you can start a session whatever it says, and each open item links to where it is fixed.
  3. When a session is running that you have not joined, press Join with the session's name. You land in the waiting room until someone running the session admits you to a role; the ribbon then shows your role and territory as the server recorded them.
  4. When the state is SEVERAL SESSIONS, press Open this session on the one you want.
  5. In SIMULATION, LIVE or FEED DOWN, an admitted exact running session's CTC board appears here when this layout has one. Read Command requests, Crew assignments visible to you, and Organization and network alerts beside or below it; Hide session context and Show session context change their visibility without closing the board. Each view has its own Refresh to read again in the exact session context, not to repeat a command, change an assignment or acknowledge an alert. Escape from the open context or its disclosure closes it and requests focus back to the disclosure. If there is no CTC panel, follow the page's guidance to generate one on the CTC page.
  6. From Dispatcher, press Open in Command Center on a layout card, or Open CTC Panel to go straight to the board.
  7. To fill crew jobs, open Crew Management for this exact session. Review each required role and position and the returned outcome. To change counts or the offered cut-over year, use the layout's Operating Rules > Train crew and then fill the new open positions. The Command Center's crew pane remains a separate last-read view.

Troubleshooting

The ribbon says NO LAYOUT. Your organization has more than one layout and none is chosen, or it has none. Choose a layout, or create your first one.

The ribbon says STARTING after I joined. You are in the waiting room. The role field says Waiting to be admitted until someone running the session admits you.

The ribbon says FEED DOWN. The session is running but the railroad's feed is not connected, or the computer hosting the session has stopped reporting its board. The Command Center shows no live state rather than a guess, and it does not switch the session to simulation.

The Command Center could not be read. Its current status is unknown, so the previous status and role are not shown as current. For the same selected session, an already-open board stays mounted with an unknown-status notice. Checks continue without repeating a command, and a successful new read restores the ribbon. If an outstanding read ignores cancellation, no overlapping workspace read starts until it returns. Changing the selected layout or session removes the old operating view immediately; a successful session-end, membership refusal or no-CTC answer also removes it.

Command requests could not be read. The board and global status ribbon remain separate from this optional read. Existing rows are labelled as last read, not current confirmation. Refresh reads records for the exact session; it never sends the command again. A read has a 15-second display budget. If a changed selection must wait for an earlier unfinished read, it has its own 15-second waiting budget before reporting unknown status. Checks cannot start another command-history operation until the outstanding one returns.

Crew assignments could not be read. Their current status is unknown. The board, global ribbon and command requests have separate reads. Any retained assignments are labelled as last read, with the last successful read time in UTC; they are not current confirmation. Refresh reads assignments for this exact session and never assigns, releases or replays a command. The view checks every 15 seconds and gives a read 15 seconds before reporting unknown status. A changed selection waiting for an earlier unfinished read has its own 15-second waiting budget. No overlapping crew read starts until that earlier operation returns.

The fill says the curated operating day is unavailable. This is a Crew Management refusal, not a Command Center read error. No jobs were filled. Review the session or layout era and the episode-authority reason; retry after that era has exactly one authoritative current episode. Refreshing this pane or using the computer's date does not resolve the missing day.

Organization and network alerts could not be read. Their current status is unknown, not an empty all-clear. Any retained rows are explicitly last-read facts. Refresh requests a new read without acknowledging an alert or repeating a command. This pane checks every 15 seconds with a 15-second display budget; a changed selection waiting behind an unfinished read has its own waiting budget. No overlapping alert read starts until the earlier operation returns. The board, ribbon, commands and crew remain separate. A changed selection clears old rows immediately; an unavailable admission or era clears them when that answer arrives. If the era is unavailable, review the selected session and layout era settings.

A request is Pending or Timed out. Pending is not confirmation. Timed out means the outcome is unknown, not that the request was refused or that the plant is safe. Read the returned reason and evidence. The view reads up to 100 recent records and also reconciles unresolved requests it already knows by key. A missing record is reported as not found, never invented or resent.

The railroad clock comes from the hosting computer. When that computer reports its clock, the ribbon shows its captured railroad time, ratio, running or stopped state, and report age as of the workspace read. It does not tick that time forward locally. A host that supplies no clock is shown as Not reported by the hosting computer. An expired board report shows Host clock unavailable: report is stale, not an old clock as current. A disconnected physical feed does not become simulation; a fresh report can still carry the hosting computer's captured clock while its railroad state is unavailable. Neither a missing clock nor recovery of a recorded host uses the web's simulation clock.

Dispatcher shows a layout as NOT RUNNING, but I created an operating session. The state counts running operating sessions on the layout. A session that has not been started, or is paused, does not make a layout running.