RailCommand Hardware Setup
Hardware Setup connects RailCommand to the DCC systems, sensors, accessories, and local runtime needed for live operation.
Before You Start
Confirm:
- The physical layout is safe.
- The correct operating layout is selected.
- Track power and boosters are in the expected state.
- Your command station, sensors, and accessories are connected.
- You know where emergency stop is available.
Setup Flow
- Open the RailCommand desktop app.
- Select the operating layout.
- Open Hardware Setup.
- Run the system check.
- Refresh hardware status.
- Run hardware detection.
- Add or edit hardware connections.
- Confirm driver, name, connection settings, capabilities, primary flag, enabled state, and auto-connect behavior.
- Start the session. Session Guidance is worth reading if a session produces less than you expect, but it is not a step before starting one; it has never been able to prevent a session from starting.
Health States
The engine banner says whether the layout engine is connecting or unavailable. Hardware Setup shows each connection as connected or not. Run system check reports Network, Backend, Localization and DCC System, each passed, warning or failed. Do not operate trains while the engine is unavailable.
In a window of its own
In the desktop app, Hardware Setup can have a window of its own: choose Open in new window on the bar at the top of the main window. It is shown in one place at a time, so it moves to that window and comes back when you open it from the main menu. Closing its window leaves a Listen and Learn run listening; open Hardware Setup again to see it. The guided setup stays in the main window: choose All hardware settings first to work in a window of its own. See Windows of their own.
A command station is shared
A command station is shared by every computer that connects to it. RailCommand never describes a connection as held by a computer, and several connections to one bus are normal. The System Check reports a command station as connected, turned off, without a port on this computer, or configured but not connected. It never reports a station as in use by another computer.
When the layout is refreshed from the website
The port a connection uses is a setting of this computer, not of the layout. When you refresh the layout from the website, each connection you set up on this computer keeps its port, its roles and whether it is turned on, as long as the refreshed layout still has that connection under the same name and system.
If the refresh removed or renamed a connection you had set up, Finish connecting says so and names the port it used. Set up offers that port again, typed in, and nothing is saved until you save it. The setting stays on this computer until a connection on the layout uses that port, a later refresh brings the connection back, or you choose Forget this setting. This happens even when the refresh left the layout with no connections.
When hardware changes are locked
While RailCommand is using this layout's connections, Hardware Setup does not change them. It says why above the connection list, and what to do:
- A session is running: end the session first.
- The real railroad is set up on the layout's connections, as Drive sets it up: choose Disconnect on its connection and do what the row says.
- A hardware task, such as a scan or Listen and Learn, is using them: let it finish.
- RailCommand still holds them on this computer: choose Connect and configure, then Disconnect all.
While they are locked, Edit and + Add connection open nothing, and a form that was open closes and says nothing was saved. Once nothing holds the connections, Edit opens the connection you chose.
Troubleshooting
If hardware is not detected:
- Confirm the command station is powered.
- Confirm cables and network connections.
- Confirm the selected driver matches the hardware.
- Confirm no other software has exclusive control of the interface.
- If the layout engine has stopped, quit RailCommand and open it again, if your operating procedure allows it.
If an imported layout's connections point at the wrong port:
- COM port numbers belong to the computer, not to the interface. A layout imported from TrainController carries the logical buses that layout declared, never a port this computer assigned, and Windows can renumber the same interface after a replug.
- Run hardware detection and choose "Use this" on the detected interface. Hardware Setup offers existing connections on the same driver that are either an imported bus with no port yet, or the same USB interface by its serial number. Choose Bind this connection, or Add as another connection. A connection whose saved USB serial number differs from the detected one is not offered. Nothing is saved until you save it.
- Binding keeps the connection's name, primary flag, enabled state, auto-connect choice, position and roles. It replaces the port and the transport settings with what detection found, including the speed the scan reports, so check the speed under Advanced transport and capabilities after binding.
- A network connection is bound to the address detection found.
- Capability roles are kept as you set them, so narrowing a connection to fewer roles than its driver supports survives a save and a rebind.
- A connection your TrainController import created, which nobody has saved since, starts with every role its interface performs by default ticked. Once you save it, the roles you left unticked stay unticked.
- A feedback bus can only listen, so it cannot be given a role that sends to the layout: a save that gives it track power, loco control, turnout control, signal control or programming is refused, and the refusal names those roles. Most feedback buses also refuse RailCom.
For manufacturer background, ask Casey about Digitrax, NCE, DCC-EX, Roco Z21, Lenz, ESU ECoS, TCS LCC/OpenLCB, or Marklin.